- Not available
TC charger 3,3kW CAN, 96V (34-132V) - 32A
3.3kW TC charger HK-J-96-32 is designed for electric vehicle LiFePO4/lithium and battery management system interface. It's a charger with high efficiency, high stability, small size, small volume and high protection grade(IP67).
Connectors included.
1. Up to 95% power efficiency and more than 93% Full Load efficiency
Basic Model |
Nominal Voltage |
Output voltage Range |
Output current -Maximum |
(CV Setting Range) |
(Max CC setting) |
||
HK-J-7240 |
72V |
18-99V |
40A |
HK-J-8240 |
84V |
25-116V |
40A |
HK-J-9632 |
96V |
34-132V |
32A |
HK-J-14423 |
144V |
50-198V |
23A |
HK-J-31210 |
312V |
110-440V |
10A |
HK-J-54006 |
540V |
170-650V |
6A |
Technical Data | |
AC Input Voltage Range | AC90V~AC265V |
AC Input Frequency | 45~65 Hz |
AC Power Factor | ≥0.98 |
Full Load Efficiency | ≥93% |
Mechanical Shock & | Conformance to |
Vibration Resistance Level |
10-25Hz Amplitude 1.2mm, 25-500Hz 30m/s2, 8hrs per direction |
Environmental Enclosure | IP67 |
Operating Temperature | -35℃~+85℃ |
Storage Temperature | -55℃~+100℃ |
Mechanical Dimensions(mm) | 239(L)*135(W)*125(H) |
Net Weight | 6.4kg |
Protection Function | |
Input Over-voltage Protection | AC270±5V |
Input Under-voltage Protection | AC85±5V |
Output Over-voltage Protection | Stop the output when exceeds +1% of the maximum output voltage |
Output Under-voltage Protection | Stop the output when below -5% of the minimum output voltage |
Output Over-current Protection | Stop the output when exceeds +1% of the maximum output current |
Over-temperature Protection | Power down from 85℃ and turn off at 90℃ |
Short-circuit Protection | Stop Output |
Battery Reverse Connect Protection | Fuse Burn-out |
Ground Protection | ≤100mΩ |
CAN communication Protection | Automatically stop the output when CAN communication fails |
Power-off Protection | Yes |
LED Status Indicator | |
1)Initial State | Red Off Green Off Red Off Green Off Red Off Green Off Red Off Green Off |
2)Charge State | Red Off Red Off Red Off Red Off Red Off Red Off Red Off Red Off |
3)Stand-by State | Green Off Green Off Green Off Green Off Green Off Green Off Green Off Green Off |
4)Fault Checking | Red Green………………....…………Wrong Battery |
Green Red…………………....………Wrong Input Voltage | |
Green Red Green……………..……Internal Temperature Protection | |
Green Red Green Red…………...Wrong Hardware | |
Red Green Red…………………..…Wrong Communication | |
Red Green Red Green……………Other error status word error |
Question & Answer:
Q :
Does this charger have any error status output aside from the LEDs? Are the fault or error messages from the charger passed through the CAN output or any other IO? thanks
A: Hello, no, the errors are signaled by the LED's, because if the CAN communication fails, only a LED signal can help for troubleshooting. Thanks.